 ======Feed, Metering and Venting section====== ======Feed, Metering and Venting section======
  
-The input mask for sections with constant flight depth is identical for the feed section, +The input mask for zones with constant channel depth are identical for the feed, meteringand degassing zones. The distinction serves to allow precise specification of the screw zones and to set the screw diameter only in the feed zone. The geometric parameters to be entered form the basis for the calculation algorithms implemented in the program and must be fully defined.
-the metering section and the degassing section. The differentiation has only been made +
-to specify the screw sections exactly and to set the diameter in the feed section. The +
-geometrical parameters to be entered from the basis of the calculation algorithms are +
-implemented in the program and must be defined completely+
  
 The following illustration shows the geometry of a single flight screw section. The following illustration shows the geometry of a single flight screw section.
Zeile 20: Zeile 16:
 |e   | Flight width | |e   | Flight width |
 |t //or// t/D   | Pitch | |t //or// t/D   | Pitch |
-| h_E, h_M, h_0    | Channel depth (**E**: Intake, **M**etering, **0**: Degassing)|+| h_E, h_M, h_0    | Channel depth (F**EE**D:, **M**etering, **0**: Degassing)|
  
-The corresponding input screen (feed zone) with the required sizes is shown below:+The corresponding input mask (feed section) with the required input data is shown below:
  
 {{ :eingabe_der_schneckendaten:rex171_einzmetentg_en_001.png?nolink |}} {{ :eingabe_der_schneckendaten:rex171_einzmetentg_en_001.png?nolink |}}
Zeile 33: Zeile 29:
 |V_K   | Channel volume | |V_K   | Channel volume |
  
-The dialogues of the metering and degassing zones differ only in the illustration and the designation of the aisle depth h_0 (degassing zone), h_M (metering zone).+The dialogues of the metering and degassing section differ only in the name of the channel depth h_0 (degassing section), h_M (metering section).
  
 {{ :eingabe_der_schneckendaten:rex171_einzmetentg_en_002.png?nolink |}} {{ :eingabe_der_schneckendaten:rex171_einzmetentg_en_002.png?nolink |}}